Author image not provided
 Boris Rubinsky

Authors:
Add personal information
  Affiliation history
Bibliometrics: publication history
Average citations per article1.86
Citation Count13
Publication count7
Publication years2007-2013
Available for download2
Average downloads per article480.00
Downloads (cumulative)960
Downloads (12 Months)41
Downloads (6 Weeks)3
SEARCH
ROLE
Arrow RightAuthor only


AUTHOR'S COLLEAGUES
See all colleagues of this author

SUBJECT AREAS
See all subject areas




BOOKMARK & SHARE


7 results found Export Results: bibtexendnoteacmrefcsv

Result 1 – 7 of 7
Sort by:

1 published by ACM
June 2013 ACM Transactions on Sensor Networks (TOSN): Volume 9 Issue 3, May 2013
Publisher: ACM
Bibliometrics:
Citation Count: 4
Downloads (6 Weeks): 3,   Downloads (12 Months): 39,   Downloads (Overall): 807

Full text available: PDFPDF
In recent years, the demand for high-precision tracking systems has significantly increased in the field of Wireless Sensor Network (WSN). A new tracking system based on exploitation of Received Signal Strength Indicator (RSSI) measurements in WSN is proposed. The proposed system is designed in particular for WSNs that are deployed ...
Keywords: Wireless sensor network, received signal strength indicator, tracking

2
January 2013 Ad Hoc Networks: Volume 11 Issue 1, January, 2013
Publisher: Elsevier Science Publishers B. V.
Bibliometrics:
Citation Count: 4

Indoor positioning systems based on Received Signal Strength Indicator (RSSI) in Wireless Sensor Networks (WSNs) are commonly used. The position accuracy in these systems is highly affected by the wireless medium variability, and therefore, a precise calibration is necessary to translate the power measurements to corresponding distance between each pair ...
Keywords: Auto-calibration, RSSI, Body area networks, Calibration

3
June 2011 WOWMOM '11: Proceedings of the 2011 IEEE International Symposium on a World of Wireless, Mobile and Multimedia Networks
Publisher: IEEE Computer Society
Bibliometrics:
Citation Count: 0

This work describes the design of a new mobile health (mHealth) platform for a continuous real time remote patient monitoring named C-SMART. The platform is based on a set of sensors for patient's physiological condition assessment, a mobile phone, and a centralized healthcare utility. C-SMART is implemented on application layer ...
Keywords: sensor programming, C-SMART, efficient seamless cellular phone, mobile health platform, mHealth platform, continuous real time remote patient monitoring, patient physiological condition assessment, mobile phone, centralized healthcare utility, application layer, telemedicine, medical data base standards, IEEE 11073, plug-and-play manner, human activity monitoring, accelerometers

4
June 2010 BSN '10: Proceedings of the 2010 International Conference on Body Sensor Networks
Publisher: IEEE Computer Society
Bibliometrics:
Citation Count: 0

This work suggests to quantify and analyze tremorusing an Ultra Wide-Band (UWB) Wireless Sensor Network(WSN). WSN based on UWB technology provides a new technology for non contact tremor assessment with extremely low radiation and penetration through walls. Tremor is the target symptom in the treatment of many neurological disorders such ...
Keywords: Tremor, UWB, Wireless Sensor

5
June 2010 BSN '10: Proceedings of the 2010 International Conference on Body Sensor Networks
Publisher: IEEE Computer Society
Bibliometrics:
Citation Count: 3

In this paper we develop a continuous high-precision tracking system based on Received Signal Strength Indicator(RSSI) measurements for small ranges. The proposed system uses minimal number of sensor nodes with RSSI capabilities to track a moving object in close-proximity and high transmission rate. The close-proximity enables conversion of RSSI measurements ...

6
June 2009 BSN '09: Proceedings of the 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks
Publisher: IEEE Computer Society
Bibliometrics:
Citation Count: 0

Continuous monitoring of internal bleeding in tissue is essential for assessment and treatment of medical conditions. In this study we present a new body sensor for diagnosis of internal tissue bleeding based on contact multi-frequency electromagnetic inductive measurements of the tissue. This contributes to the existing family of body network ...
Keywords: body network sensors, bleeding, Weiner filter, wearable, emergency medicine

7
April 2007 Journal of Biomedical Imaging: Volume 2007 Issue 2, April 2007
Publisher: Hindawi Limited
Bibliometrics:
Citation Count: 0
Downloads (6 Weeks): 1,   Downloads (12 Months): 1,   Downloads (Overall): 152

Full text available: PDFPDF
Electrical impedance tomography (EIT) produces an image of the electrical impedance distribution of tissues in the body, using electrodes that are placed on the periphery of the imaged area. These electrodes inject currents and measure voltages and from these data, the impedance can be computed. Traditional EIT systems usually inject ...



The ACM Digital Library is published by the Association for Computing Machinery. Copyright © 2018 ACM, Inc.
Terms of Usage   Privacy Policy   Code of Ethics   Contact Us