Abstract

We propose a flexible new technique to easily calibrate a camera. It only requires the camera to observe a planar pattern shown at a few (at least two) different orientations. Either the camera or the planar pattern can be freely moved. The motion need not be known. Radial lens distortion is modeled. The proposed procedure consists of a closed-form solution, followed by a nonlinear refinement based on the maximum likelihood criterion. Both computer simulation and real data have been used to test the proposed technique and very good results have been obtained. Compared with classical techniques which use expensive equipment such as two or three orthogonal planes, the proposed technique is easy to use and flexible. It advances 3D computer vision one more step from laboratory environments to real world use. The corresponding software is available from the author's Web page.

References

  1. S. Bougnoux, “From Projective to Euclidean Space under any Practical Situation, a Criticism of Self-Calibration,” Proc. Sixth Int'l Conf. Computer Vision, pp. 790-796, Jan. 1998. Google ScholarGoogle ScholarDigital LibraryDigital Library
  2. D.C. Brown, “Close-Range Camera Calibration,” Photogrammetric Eng., vol. 37, no. 8, pp. 855-866, 1971.Google ScholarGoogle Scholar
  3. B. Caprile and V. Torre, “Using Vanishing Points for Camera Calibration,” Int'l J. Computer Vision, vol. 4, no. 2, pp. 127-140, Mar. 1990. Google ScholarGoogle ScholarDigital LibraryDigital Library
  4. W. Faig, “Calibration of Close-Range Photogrammetry Systems: Mathematical Formulation,” Photogrammetric Eng. and Remote Sensing, vol. 41, no. 12, pp. 1,479-1,486, 1975.Google ScholarGoogle Scholar
  5. O. Faugeras, Three-Dimensional Computer Vision: A Geometric Viewpoint. MIT Press, 1993. Google ScholarGoogle ScholarDigital LibraryDigital Library
  6. O. Faugeras T. Luong and S. Maybank, “Camera Self-Calibration: Theory and Experiments,” Proc Second European Conf. Computer Vision, pp. 321-334, May 1992. Google ScholarGoogle ScholarDigital LibraryDigital Library
  7. O. Faugeras and G. Toscani, “The Calibration Problem for Stereo,” Proc. IEEE Conf. Computer Vision and Pattern Recognition, pp. 15-20, June 1986.Google ScholarGoogle Scholar
  8. S. Ganapathy, “Decomposition of Transformation Matrices for Robot Vision,” Pattern Recognition Letters, vol. 2, pp. 401-412, Dec. 1984.Google ScholarGoogle ScholarDigital LibraryDigital Library
  9. D. Gennery, “Stereo-Camera Calibration,” Proc. 10th Image Understanding Workshop, pp. 101-108, 1979.Google ScholarGoogle Scholar
  10. G. Golub and C. van Loan, Matrix Computations, Baltimore: The John Hopkins Univ. Press, third ed. 1996.Google ScholarGoogle Scholar
  11. R. Hartley, “Self-Calibration from Multiple Views with a Rotating Camera,” Proc. Third European Conf. Computer Vision, pp. 471-478, May 1994. Google ScholarGoogle ScholarDigital LibraryDigital Library
  12. R.I. Hartley, “An Algorithm for Self-Calibration from Several Views,” Proc. IEEE Conf. Computer Vision and Pattern Recognition, pp. 908-912, June 1994.Google ScholarGoogle ScholarCross RefCross Ref
  13. D. Liebowitz and A. Zisserman, “Metric Rectification for Perspective Images of Planes,” Proc. IEEE Conf. Computer Vision and Pattern Recognition, pp. 482-488, June 1998. Google ScholarGoogle ScholarDigital LibraryDigital Library
  14. Q.-T. Luong, “Matrice Fondamentale et Calibration Visuelle sur l'Environnement-Vers une plus Grande Autonomie des Systèmes Robotiques,” PhD thesis, Université de Paris-Sud, Centre d'Orsay, Dec. 1992.Google ScholarGoogle Scholar
  15. Q.-T. Luong and O. Faugeras, “Self-Calibration of a Moving Camera from Point Correspondences and Fundamental Matrices,“ Int'l J. Computer Vision, vol. 22, no. 3, pp. 261-289, 1997. Google ScholarGoogle ScholarDigital LibraryDigital Library
  16. S.J. Maybank and O.D. Faugeras, “A Theory of Self-Calibration of a Moving Camera,” Int'l J. Computer Vision, vol. 8. no. 2, pp. 123-152, Aug. 1992. Google ScholarGoogle ScholarDigital LibraryDigital Library
  17. J. More, “The Levenberg-Marquardt Algorithm, Implementation, and Theory,” Numerical Analysis, G.A. Watson, ed., Springer-Verlag, 1977.Google ScholarGoogle Scholar
  18. J. Semple and G. Kneebone, Algebraic Projective Geometry. Oxford: Clarendon Press, 1952.Google ScholarGoogle Scholar
  19. I. Shimizu Z. Zhang S. Akamatsu and K. Deguchi, “Head Pose Determination from One Image Using a Generic Model,” Proc. IEEE Third Int'l Conf. Automatic Face and Gesture Recognition, pp. 100-105, Apr. 1998. Google ScholarGoogle ScholarDigital LibraryDigital Library
  20. G. Stein, “Accurate Internal Camera Calibration Using Rotation, with Analysis of Sources of Error,” Proc. Fifth Int'l Conf. Computer Vision, pp. 230-236, June 1995. Google ScholarGoogle ScholarDigital LibraryDigital Library
  21. P. Sturm and S. Maybank, “On Plane-Based Camera Calibration: A General Algorithm, Singularities, Applications,” Proc. IEEE Conf. Computer Vision and Pattern Recognition, pp. 432-437, June 1999.Google ScholarGoogle ScholarCross RefCross Ref
  22. B. Triggs, “Autocalibration from Planar Scenes,” Proc. Fifth European Conf. Computer Vision, pp. 89-105, June 1998. Google ScholarGoogle ScholarDigital LibraryDigital Library
  23. R.Y. Tsai, “A Versatile Camera Calibration Technique for High-Accuracy 3D Machine Vision Metrology Using Off-the-Shelf TV Cameras and Lenses,” IEEE J. Robotics and Automation, vol. 3, no. 4, pp. 323-344, Aug. 1987.Google ScholarGoogle ScholarCross RefCross Ref
  24. G. Wei and S. Ma, “A Complete Two-Plane Camera Calibration Method and Experimental Comparisons,” Proc. Fourth Int'l Conf. Computer Vision, pp. 439-446, May 1993.Google ScholarGoogle ScholarCross RefCross Ref
  25. J. Weng P. Cohen and M. Herniou, “Camera Calibration with Distortion Models and Accuracy Evaluation,” IEEE Trans. Pattern Analysis and Machine Intelligence, vol. 14, no. 10, pp. 965-980, Oct. 1992. Google ScholarGoogle ScholarDigital LibraryDigital Library
  26. Z. Zhang, “A Flexible New Technique for Camera Calibration,” Technical Report MSR-TR-98-71, Microsoft Research, Dec. 1998. Available together with the software at http://research.microsoft.com/~zhang/Calib/.Google ScholarGoogle Scholar

Index Terms

  1. A Flexible New Technique for Camera Calibration

    Recommendations

    Comments

    Login options

    Check if you have access through your login credentials or your institution to get full access on this article.

    Sign in

    Full Access