Abstract
We investigate the impact of wireless channel temporal variations on the design of medium access control (MAC) protocols for body area networks (BANs). Our measurements-based channel model captures large and small time-scale signal correlations, giving an accurate picture of the signal variation, specifically, the deep fades which are the features that mostly affect the behavior of the MAC. We test the effect of the channel model on the performance of the 802.15.4 MAC both in contention access mode and TDMA access mode. We show that there are considerable differences in the performance of the MAC compared to simulations that do not model channel temporal variation. Furthermore, explaining the behavior of the MAC under a temporal varying channel, we can suggest specific design choices for the emerging BAN MAC standard.
- Cotton, S. L. and Scanlon, W. G. 2007. Characterization and modeling of the indoor radio channel at 868 MHz for a mobile bodyworn wireless personal area network. IEEE Antennas Wire. Propag. Lett. 6, 51--55.Google Scholar
Cross Ref
- Davenport, D., Seidl, N., Moss, J., Patel, M., Batra, A., Ho, J., Hosur, S., Roh, J., Schmidl, T., Omeni, O., and Wong, A. 2009a. MedWin physical layer proposal documentation. IEEE Document P802.15.09-0329-00-0006.Google Scholar
- Davenport, D., Seidl, N., Moss, J., Patel, M., Batra, A., Ho, J., Hosur, S., Roh, J., Schmidl, T., Omeni, O., and Wong, A. 2009b. MedWin MAC and security proposal documentation. IEEE Document 802.15-09-0326-01-0006.Google Scholar
- Ding, G. 2009. Olympus MAC proposal presentation. IEEE Document P802.15-09-0311-00-0006.Google Scholar
- Fort, A., Rucjaert, J., Desset, C., and De Doncker, P. 2006. Ultra-wideband channel model for communication around the human body. IEEE J. Select. Areas Commun. 24, 4, 927--933. Google Scholar
Digital Library
- Hanlen, L. W., Miniutti, D., Rodda, D., and Gilbert, B. 2009. Interference in body area networks: Distance does not dominate. In Proceedings of the International Symposium on Personal Indoor and Mobile Radio Communication.Google Scholar
- Miniutti, D., Hanlen, L. W., Smith, D. B., Zhang, J., Rodda, D., Gilbert, B., and Gengfa, F. 2009. NICTA proposal. IEEE Document P802.15-09-0345-00-0006.Google Scholar
- Omeni, O., Chi Wai Wong, A., Burdett, A. J., and Tomazou, C. 2008. Energy efficient medium access protocol for wireless medical body area sensor networks. IEEE Trans. Biomed. Circuits Syst 2, 4, 251--259.Google Scholar
Cross Ref
- Reusens, E., Joseph, W., Vermeeren, G., and Martens, L. 2007. On-body measurements and characterization of wireless communication channel for arm and torso of human. In Proceedings of the 4th International Workshop on Wearable and Implantable Body Sensor Networks. 264--269.Google Scholar
- Su, H. and Zhang, X. 2009. Battery-dynamics driven TDMA MAC protocols for wireless body-area monitoring networks in healthcare applications. IEEE J. Select. Areas Commun. 27, 4, 424--434. Google Scholar
Digital Library
- Timmons, N. F. and Scanlon, W. G. 2004. Analysis of the performance of IEEE 802.15.4 for medical sensor body area networking, In Proceedings of the 1st Annual IEEE Communications Society Conference on Sensor and Ad Hoc Communications and Networks. 16--24.Google Scholar
- Timmons, N. F. and Scanlon, W. G. 2009. An adaptive energy efficient MAC protocol for the medical body area network. In Proceedings of the 1st International Conference-Wireless Communication, Vehicular Technology, Information Theory and Aerospace & Electronic Systems Technology. 587--593.Google Scholar
- Zhang, J., Smith, D. B., Hanlen, L. W., Miniutti, D., Rodda, D., and Gilbert, B. 2009. Stability of narrowband dynamic body area channel, IEEE Antennas and Wireless Propagation Letters, 2009. Stability of narrowband dynamic body area channel. IEEE Antennas Wirel. Propag. Lett.Google Scholar
- Zhen, B., Patel, M., Lee, S., Won, E., and Astrin, A. 2008. IEEE 802.15.6 Technical Requirements Document, IEEE Document 802.15-08-0644-09-0006.Google Scholar
Index Terms
Impact of Wireless Channel Temporal Variation on MAC Design for Body Area Networks
Recommendations
A MAC protocol for cognitive wireless sensor body area networking
In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-...
A MAC protocol for reliable communication in low power body area networks
Wireless Body Area Networks (BAN) are supposed to operate in very low transmit power regime in order to keep the Specific Absorption Rate (SAR) low. Low power transmissions are known to be very error prone. However, high reliability of communications is ...
Dynamic backoff scheduling of low data rate applications in wireless body area networks
Reliability stands as the first important factor when dealing with medical data within the context of a wireless body area network (WBAN). The sensor nodes on body send their data to the coordinator based on a beacon-enabled access mode defined in IEEE ...






Comments