ABSTRACT
Disease surveillance is essential for the control of flu and respiratory infectious diseases including the novel coronavirus disease (COVID-19). Indoor air quality monitoring has been shown effective in understanding the effectiveness of airflow and circulation indoors to reduce the risk of infectious diseases. In this project, we developed low-cost indoor air quality monitoring devices and systems to tackle the disease surveillance problem. The monitoring device consists of a set of air quality sensors. By strategic deployment and real-time data analysis, the system is able to yield insightful air circulation information indoors. The real-time data analysis is performed on air quality for the indoor ventilation using Long Short-Term Memory (LSTM) on sensed data. A series of user-friendly visualization interfaces and chatbot applications are designed to interact with users and ensure the successful delivery of infection control information. Finally, we work closely with the Taiwan Centers for Disease Control (CDC) and conduct field experiments in 15 locations including hospitals, long-term care centers, schools with total of 144 IAQ devices.
- L.-J. Chen et al. An Open Framework for Participatory PM2.5 Monitoring in Smart Cities. IEEE Access, vol. 5, pp. 14441--14454, 2017.Google Scholar
- L.-J. Chen et al. LASS: A Location-Aware Sensing System for Participatory PM2.5 Monitoring. ACM/USENIX International Conference on Mobile Systems, Applications, and Services (MobiSys'16), Singapore, June 2016.Google Scholar
- S Hochreiter, J Schmidhuber. Long Short-Term Memory, Neural computation 9 (8), 1735--1780. 1997.Google Scholar
Digital Library
- C. M. Issarow, N. Mulder, R. Wood. Modelling the risk of airborne infectious disease using exhaled air. Journal of Theoretical Biology Vol. 372 (7) 100--106 May 2015.Google Scholar
Cross Ref
- A.C. Lowen et al. High Temperature (30 C) Blocks Aerosol but Not Contact Transmission of Influenza Virus. J Virol 2008; 82(11): 5650--2.Google Scholar
- J. A. Metz and A. Finn. Influenza and Humidity - Why a bit more damp may be good for you! Journal of Infection Vol. 71, S54--58, 2015.Google Scholar
- OASIS Standard. Message Queuing Telemetry Transport (MQTT) version 3.1.1. http://mqtt.org, October 2014.Google Scholar
- S. N. Rudnick and D. K. Milton. Risk of Indoor Airborne Infection Transmission Estimated from Carbon Dioxide Concentration. Indoor Air. Vol. 13: 237--245. 2003.Google Scholar
Cross Ref
- R. Wood, C. Morrow, S. Ginsber, et al. Quantification of Shared Air: A Social and Environmental Determinant of Airborne Disease Transmission. PLoS One 2014; 9(2): e 0106622.Google Scholar
- W. Yang, S. Elankumaran, L. Marr. Relationship between Humidity and Influenza A Viability in Droplets and Implicaiton for Influenza's Seasonality. PLoS One 2012; 7(10): e46789.Google Scholar
Index Terms
Indoor air quality monitoring system for proactive control of respiratory infectious diseases: poster abstract
Recommendations
Monitoring Indoor Air Quality for Enhanced Occupational Health
Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of ...
Applied Patent RFID Systems for Building Reacting HEPA Air Ventilation System in Hospital Operation Rooms
AbstractRFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ...
Analysis of Pediatric Respiratory Disease Trends Using the 2016 KIDs' Inpatient Database
Many infants and young children worldwide have been affected by chronic respiratory conditions. In this paper, the authors performed an exploratory and predictive analysis of the 2016 KID data set to examine respiratory disease trends among children. ...





Comments